<ArticleTitle>Suitable Energy Dissipation Device for Private Typical Buildings with Poor Seismic Performance</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>131</FirstPage>
			<LastPage>143</LastPage>
			<ELocationID EIdType="pii">240637</ELocationID>
			
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Seyed Mehdi</FirstName>
					<LastName>Zahrai</LastName>
<Affiliation>The University of Tehran</Affiliation>
<Identifier Source="ORCID">0000-0003-2759-2424</Identifier>

</Author>
<Author>
					<FirstName>Seyed Amin</FirstName>
					<LastName>Mousavi</LastName>
<Affiliation>Sabok Sazan Sarie Company</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2014</Year>
					<Month>09</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		<Abstract>Different kinds of passive and active control methods, their advantages and disadvantages, and their feasibility for buildings in Iran are investigated during this study. The main focus of this study is on passive control techniques used in private typical buildings with relatively low seismic performance, which are quite common in Iran. This study also includes a brief outline of different passive dampers and vibration absorbers. According to the technical and economical issues, it is shown that tuned liquid column-gas damper, TLCGD, is one of the best options for enhancing the seismic behavior of typical buildings in the country. A simple yet accurate procedure is proposed to estimate equivalent damping ratio corresponding to the TLCGD. Finally, through a numerical assessment, effect of TLCGD is investigated. Based on the obtained results, TLCGD can reduce rout mean square (RMS) response of buildings, but its capability in reducing the maximum response depends on the excitation itself. TLCGD was shown an efficient scheme for enhancement of seismic capacity of both new and under-operation existing buildings.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Passive Control</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">TLCGD</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Vibration Absorber</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Seismic Retrofit</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Seismic Excitation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Equivalent Damping Ratio</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jsee.ir/article_240637_81c545ace4a069319ddf9e1884b075c9.pdf</ArchiveCopySource>
</Article>
</ArticleSet>